A Comparison of Finite Element Simulation and Experimental Results from Reinforced Concrete Columns Wrapped with Fibre-Reinforced Polymer Subjected to Blast Loading

A Comparison of Finite Element Simulation and Experimental Results from Reinforced Concrete Columns Wrapped with Fibre-Reinforced Polymer Subjected to Blast Loading

Jeslin Quek Liu Chunlin John Vincent Musngi Pavithra Buddika Malalasekara

Fyfe Asia Pte Ltd.

K&C Protective Technologies Pte Ltd.

Page: 
233-242
|
DOI: 
https://doi.org/10.2495/CMEM-V8-N3-233-242
Received: 
N/A
|
Revised: 
N/A
|
Accepted: 
N/A
|
Available online: 
N/A
| Citation

© 2020 IIETA. This article is published by IIETA and is licensed under the CC BY 4.0 license (http://creativecommons.org/licenses/by/4.0/).

OPEN ACCESS

Abstract: 

Fibre-reinforced polymer (FRP) as a protective hardening system has now become more commonly used in enhancing the capacity of reinforced concrete (RC) elements against blast loadings. Wrapping RC columns with FRP, depending on the wrapping configuration, will result in additional axial, moment and shear capacity. The FRP also prevents debris from being blown off and serves as a catcher system which minimises the possible cause of injuries/casualties in the event of blast. While analytical models built into popular finite element modelling (FEM) software are widely used to simulate and analyse the effects of a blast load to a structural element, little work has been carried out to validate the results of such analysis through experimental means. This paper examines the effect of blast loadings onto RC columns wrapped with FRP. The behaviour of the FRP-wrapped RC columns subjected to blast loading is simulated using finite element analysis. Results from the finite element simulation are compared to the corresponding wrapping configuration from actual experimental results. The comparison validates the reliability of using finite element analysis in predicting the response of FRP-wrapped RC columns subjected to blast loading.

Keywords: 

blast mitigation, fibre-reinforced polymer, finite element simulation

  References

[1] Joint Operations Group - Ministry of Home Affairs, Guidelines for Enhancing BuildingSecurity in Singapore (GEBSS). https://www.mha.gov.sg/docs/default-source/others/mha_guidelines_for_enhancing_building_security_in_singapore_2018.pdf. Accessedon: 22 Dec. 2019.

[2] Singapore Statutes Online, Infrastructure Protection Act 2017 (No. 41 of 2017), Governmentof Singapore. https://sso.agc.gov.sg/Acts-Supp/41-2017/Published/20171031?DocDate=20171031. Accessed on: 25 Jan. 2020.

[3] ACI committee 440, Guide for the design and construction of externally bonded FRPsystems for strengthening existing structures (ACI 440.2R-17), 2017.

[4] The Concrete Society, Design guidance for strengthening concrete structures usingfibre composite materials, Technical Report 55 (3rd Edition). The Concrete Society,Camberley, 2012.

[5] U.S. Army Corps of Engineers, Structures to Resist the Effects of Accidental Explosions(UFC 3-340-02), 2008.

[6] Quek, J., & Ow, M.C., SDOF analysis of protective hardening design for reinforcedconcrete columns using fibre reinforced polymer wrap. Proceedings of the Fourth Asia-Pacific Conference on FRP in Structures (APFIS 2013), 2013.

[7] Kingery, C. N., Bulmash, G., & U.S. Army Ballistic Research Laboratory. Air blastparameters from TNT spherical air burst and hemispherical surface burst. AberdeenProving Ground, MD: Ballistic Research Laboratories, 1984.

[8] Jacques, E., Lloyd, A., Imbeau, P., Palermo, D., & Quek, J., GFRP-retrofitted reinforcedconcrete columns subjected to simulated blast loading. Journal of Structural Engineering,141(11), 04015028, 2015. doi:10.1061/(ASCE)ST.1943-541X.0001251