A Sustainable Prototype for Renewable Energy: Optimized Prime-Power Generator Solar Array Replacement

A Sustainable Prototype for Renewable Energy: Optimized Prime-Power Generator Solar Array Replacement

Nathan Thomsen Torrey Wagner Andrew Hoisington Steven Schuldt

Department of Systems Engineering and Management, Air Force Institute of Technology, Wright-Patterson Air Force Base, USA

Page: 
28-39
|
DOI: 
https://doi.org/10.2495/EQ-V4-N1-28-39
Received: 
N/A
| |
Accepted: 
N/A
| | Citation

OPEN ACCESS

Abstract: 

Remote locations such as disaster relief camps, isolated arctic communities, and military forward operating bases are disconnected from traditional power grids forcing them to rely on diesel generators with a total installed capacity of 10,000 MW worldwide. The generators require a constant resupply of fuel, resulting in increased operating costs, negative environmental impacts, and challenging fuel logistics. To enhance remote site sustainability, planners can develop stand-alone photovoltaic-battery systems to replace existing prime power generators. This paper presents the development of a novel cost-performance model capable of optimizing solar array and Li-ion battery storage size by generating tradeoffs between minimizing initial system cost and maximizing power reliability. A case study for the replacement of an 800 kW generator, the US Air Force’s standard for prime power at deployed locations, was analyzed to demonstrate the model and its capabilities. A MATLAB model, simulating one year of solar data, was used to generate an optimized solution to minimize initial cost while providing over 99% reliability. Replacing a single diesel generator would result in a savings of 1.9 million liters of fuel, eliminating 100 fuel tanker truck deliveries annually. The distinctive capabilities of this model enable designers to enhance environmental, economic, and operational sustainability of remote locations by creating energy self-sufficient sites, which can operate indefinitely without the need for resupply. 

Keywords: 

battery, diesel generator, energy storage, isolated sites, optimization, photovoltaic, renewable energy, solar array, stand-alone

  References

[1] Arriaga, M., Canizares, C.A. & Kazerani, M., Northern lights: Access to electricity in Canada’s Northern and remote communities. IEEE Power and Energy Magazine, 12(4), pp. 50–59, July 2014.

[2] Schill, D., Improving energy security for air force installations. RAND Corp Santa Monica, CA, 2015.

[3] United States Government Accountability Office (US GAO), GAO-09-300 Defense Management: DOD Needs to Increase Attention on Fuel Demand Management at Forward-Deployed Locations. 2009.

[4] Number, S., Chadwick, B. & Mullins, J., Sustainable forward operating bases. Strategic Environmental Research and Development Program (SERDP). Noblis, 2015.

[5] Eady, D.S., Siegel, S.B., Bell, R.S. & Dicke, S.h., Sustain the Mission Project: Casualty Factors for Fuel and Water Resupply Convoys. Army Environmental Policy Institute (AEPI), Arlington, vA, 2009.

[6] Saheb-Koussa, D., haddadi, M. & Belhamel, M., Economic and technical study of a hybrid system (wind-photovoltaic-diesel) for rural electrification in Algeria. Applied Energy, 86(7–8), pp. 1024–1030, 2009.

[7] Askarzadeh, A., Distribution generation by photovoltaic and diesel generator sys- tems: Energy management and size optimization by a new approach for a stand-alone application. Energy, 122(1), pp. 542–551, March 2017.

[8] Akinyele, D., Analysis of photovoltaic mini-grid systems for remote locations: A techno- economic approach. International Journal of Energy Research, 42(3), pp. 1363–1380, March 2018.

[9] Yilmaz, S., Ozcalik, h.R., Kesler, S., Dincer, F. & Yelmen, B., The analysis of different Pv power systems for the determination of optimal Pv panels and system installation- A case study in Kahramanmaras, Turkey. Renewable and Sustainable Energy Reviews, 52, pp. 1015–1024, December 2015.

[10] Perera, A.T.D., Attalage, R.A., Perera, K. & Dassanayake, v., Designing standalone hybrid energy systems minimizing initial investment, life cycle cost and pollutant emission. Energy, 54, pp. 220–230, 2013.

[11] International Energy Agency, Renewables 2017: A New Era for Solar Power, 2017.

[12] Chester, D.J., Wagner, T.J. & Dudis, D., 36% reduction in FOB generator fuel use with optimized energy storage. Marine Corps Gazette, 103(3), 2019.

[13] Wagner, T., Lang, E., Assink, W. & Dudis, D., Photovoltaic system optimization for  an austere location using time-series data. Proceedings of the IEEE 45th Photovoltaic Specialists Conference, pp. 0–4, 2018.

[14] McCaskey,  N.C.,   Renewable   Energy   Systems   for   Forward   Operating   Bases: A Simulations-Based Optimization Approach, Colorado State University, 2010.

[15] Kosowatz, J., Military Looks to Renewables in Battle Zones. ASME Online. https:// asme.org/engineering-topics/articles/energy/military-looks-renewables-battle-zones (accessed 14 October 2018).

[16] Keith, M.v., Moheisen, R.M., Shaaban, A.h. & Salavani, R., Photovoltaic (PV) Integrated Power Shelter Systems for Basic Expeditionary Airfield Resources (BEAR), 2012.

[17] USAF, 635th Materiel Maintenance Group. Definitive Guide to BEAR Base Assets, 2017.

[18] USAF, Air Force Tactics, Techniques, and Procedures AFTTP3-32.34V5 - Contingency Electrical Power Production and Distribution Systems, 2017.

[19] U.S. Bureau of Labor Statistics, “CPI (Consumer Price Index).” Online https://bls.gov/ cpi/home.htm (accessed 18 November 2018).

[20] Diorio, N., Dobos, A. & Janzou, S., Economic Analysis Case Studies of Battery Energy Storage with SAM. National Renewable Energy Laboratory, 2015.