Coupled heat and moisture transfer features of typical external thermal insulation systems

Coupled heat and moisture transfer features of typical external thermal insulation systems

Yang WangXiaoyu Hu Shiyong Wu 

Department of Building Engineering, Hefei University, Hefei 230601, China

School of Management, Jinan University, Guangzhou 510632, China

Corresponding Author Email: 
122432892@qq.com
Page: 
1362-1366
|
DOI: 
https://doi.org/10.18280/ijht.360427
Received: 
2 March 2018
| |
Accepted: 
10 July 2018
| | Citation

OPEN ACCESS

Abstract: 

Targeting three typical external thermal insulation systems, this paper puts forward a new principle (change of capacitive reactance of high-frequency electromagnetic wave sensors) for measuring the temperature and humidity in the interface between different layers of exterior walls. Following this method, several other ways such as thermal calculations, software simulations and model analyses are compared with each other to evaluate the actual thermal insulation and heat transfer effects of the walls, discuss the causes of thermal insulation defects and the solutions to remedy these defects. The research findings provide a valuable reference for the design, construction, application, evaluation and repair of energy-saving walls in hot summer and cold winter areas.

Keywords: 

external thermal insulation (ETI), exterior wall, moisture content, coupled heat and moisture, thermal insulation effect.

1. Introduction
2. Experimental Design and Procedure
3. Calculation and Analysis of Experimental Results
4. Comparison with Simulated and Analytical Values
5. Conclusions
Acknowledgement
  References

[1] Ham Y, Mani M. (2013). Calculating the cost of heating and cooling loss for building diagnostics using EPAR - energy performance augmented reality- models. Computing in Civil Engineering 242-249. https://doi.org/10.1061/9780784413029.031

[2] Fazio P, Athienitis K, Marsh C, Rao JW. (1997). Environmental chamber for investigation of building envelope performance. J. Archit. Eng. 3(2): 97-102. https://doi.org/10.1061/(ASCE)1076-0431(1997)3:2(97)

[3] Feng R, Li JP, Li XZ. (2016). Performance study of external wall insulation and a hybrid energy supply system for a rural residential building. Journal of Energy Engineering 142(4). https://doi.org/10.1061/(ASCE)EY.1943-7897.0000366

[4] Barreira E, Freitas VPD. (2007). Evaluation of building materials using infrared thermography. Construction and Building Materials 21: 218-224. https://doi.org/10.1016/j.conbuildmat.2005.06.049

[5] Blaise KK, Magloire KEP, Prosper G. (2018). Thermal performance evaluation of an indirect solar dryer. Instrumentation, Mesure, Métrologie 17(1): 131-151 http://dx.doi.org/10.3166/I2M.17.131-151

[6] Zheng KK, Cho YK, Wang C, Li HR. (2016). Noninvasive residential building envelope R-value measurement method based on inter facial thermal resistance. J. Archit. Eng. 22(4): A4015002. https://doi.org/10.1061/(ASCE)AE.1943-5568.0000182.

[7] Barreira1 E, Vasco P, Freitas D. (2016). Evaluation of surface humidification of exterior insulation and finish systems. J. Perform. Constr. Facil. 30(2): 04015026. https://doi.org/10.1061/(ASCE)CF.1943-5509.0000777

[8] Amir A, Strand RK, Hammann RE, Bhandari MS. (2018). Determination and assessment of optimum internal thermal insulation for masonry walls in historic multifamily buildings. J. Archit. Eng. 24(3): 04018016. https://doi.org/10.1061/(ASCE)AE.1943- 5568.0000320

[9] Liu YF. (2016). Research on the effect of moisture transfer on heat transfer coefficient of building enclosure. Master Dissertation 2016, Xi'an University of Architectural Science and Technology 19-47.

[10] Wang ZH. (2006). Basic research of confirm moisture stability and the infrared method for thermal performance qualitative detection of thermal irregularities in building envelops. Master Dissertation 2006, Harbin University of Technology 25-48.

[11] Liu XW. (2009). Investigation of the coupled heat, air and moisture transport in building walls in hot summer and cold winter zone. Doctoral Dissertation 2009, Hunan University, China 55-89.